58 research outputs found

    Ischemic and Bleeding Risk After Percutaneous Coronary Intervention in Patients With Prior Ischemic and Hemorrhagic Stroke

    Get PDF
    Background: Prior stroke is regarded as risk factor for bleeding after percutaneous coronary intervention (PCI). However, there is a paucity of data on detailed bleeding risk of patients with prior hemorrhagic and ischemic strokes after PCI. Methods and Results: In a pooled cohort of 19 475 patients from 3 Japanese PCI studies, we assessed the influence of prior hemorrhagic (n=285) or ischemic stroke (n=1773) relative to no-prior stroke (n=17 417) on ischemic and bleeding outcomes after PCI. Cumulative 3-year incidences of the co-primary bleeding end points of intracranial hemorrhage, non-intracranial global utilization of streptokinase and tissue plasminogen activator for occluded coronary arteries (GUSTO) moderate/severe bleeding, and the primary ischemic end point of ischemic stroke/myocardial infarction were higher in the prior hemorrhagic and ischemic stroke groups than in the no-prior stroke group (6.8%, 2.5%, and 1.3%, P<0.0001, 8.8%, 8.0%, and 6.0%, P=0.001, and 12.7%, 13.4%, and 7.5%, P<0.0001). After adjusting confounders, the excess risks of both prior hemorrhagic and ischemic strokes relative to no-prior stroke remained significant for intracranial hemorrhage (hazard ratio (HR) 4.44, 95% CI 2.64-7.01, P<0.0001, and HR 1.52, 95% CI 1.06-2.12, P=0.02), but not for non-intracranial bleeding (HR 1.18, 95% CI 0.76-1.73, P=0.44, and HR 0.94, 95% CI 0.78-1.13, P=0.53). The excess risks of both prior hemorrhagic and ischemic strokes relative to no-prior stroke remained significant for ischemic events mainly driven by the higher risk for ischemic stroke (HR 1.46, 95% CI 1.02-2.01, P=0.04, and HR 1.49, 95% CI 1.29-1.72, P<0.0001). Conclusions: Patients with prior hemorrhagic or ischemic stroke as compared with those with no-prior stroke had higher risk for intracranial hemorrhage and ischemic events, but not for non-intracranial bleeding after PCI

    Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan

    Get PDF
    Background: Diagnostic reference levels (DRLs) have not been established in Japan. Objective: To propose DRLs for CT of the head, chest and abdomen for three pediatric age groups. Materials and methods: We sent a nationwide questionnaire by post to 339 facilities. Questions focused on pediatric CT technology, exposure parameters, CT protocols, and radiation doses for age groups <1 year, 1-5 years, and 6-10 years. Results: For the three age groups in the 196 facilities that responded, the 75th percentile values of volume CT dose index based on a 16-cm phantom (CTDIvol 16 [mGy]) for head, chest and abdominal CT were for infants 39.1, 11.1 and 12.0, respectively; for 1-to 5-year-olds 46.9, 14.3 and 16.7, respectively; and for 6-to 10-year-olds 67.7, 15.0 and 17.0, respectively. The corresponding dose–length products (DLP 16 [mGy・cm]) for head, chest and abdominal CT were for infants 526.1, 209.1 and 261.5, respectively; for 1-to 5-year-olds 665.5, 296.0 and 430.8, respectively; and for 6-to 10-year-olds 847.9, 413.0 and 532.2, respectively. Conclusion: The majority of CTDIvol 16 and DLP 16 values for the head were higher than DRLs reported from other countries. For risk reduction, it is necessary to establish DRLs for pediatric CT in Japan. © 2015 Springer-Verlag Berlin HeidelbergEmbargo Period 12 month

    Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies

    Full text link
    Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneously provide the photon energy measurement and enable material decomposition for spectral imaging. In this work, we report a performance evaluation of our first CdZnTe-based prototype full-size photon counting CT system through various phantom imaging studies. This prototype system supports a 500 mm scan field-of-view (FOV) and 10 mm cone coverage at isocenter. Phantom scans were acquired using 120 kVp from 50 to 400 mAs to assess the imaging performance on: CT number accuracy, uniformity, noise, spatial resolution, material differentiation and quantification. Both qualitative and quantitative evaluations show that PCCT has superior image quality with lower noise and improved spatial resolution compared to conventional energy integrating detector (EID)-CT. Using projection domain material decomposition approach with multiple energy bin measurements, PCCT virtual monoenergetic images (VMIs) have lower noise, and superior performance in quantifying iodine and calcium concentrations. These improvements lead to increased contrast-to-noise ratio (CNR) for both high and low contrast study objects and can significantly reduce the iodine contrast agent to achieve the same CNR as EID-CT. PCCT can also generate super-high resolution (SHR) images using much smaller detector pixel size than EID-CT and dramatically push the spatial resolution limit. These initial results demonstrate that PCCT based on CdZnTe detectors has huge potential in clinical settings

    Long-Term Voyages and Bone Mass Among Seamen

    Get PDF
    東京水産大学海洋生産学専攻東京水産大学練習船海鷹丸東京水産大学練習船神鷹丸東京水産大学練習船海鷹丸東京水産大学練習船海鷹丸東京水産大学練習船神鷹丸東京水産大学練習船神鷹丸東京水産大学練習船海鷹丸東京水産大学練習船神鷹丸東京水産大学海洋生産学科東京水産大学海洋生産学

    CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) in 2018

    Get PDF
    While primary percutaneous coronary intervention (PCI) has significantly contributed to improve the mortality in patients with ST segment elevation myocardial infarction even in cardiogenic shock, primary PCI is a standard of care in most of Japanese institutions. Whereas there are high numbers of available facilities providing primary PCI in Japan, there are no clear guidelines focusing on procedural aspect of the standardized care. Whilst updated guidelines for the management of acute myocardial infarction were recently published by European Society of Cardiology, the following major changes are indicated; (1) radial access and drug-eluting stent over bare metal stent were recommended as Class I indication, and (2) complete revascularization before hospital discharge (either immediate or staged) is now considered as Class IIa recommendation. Although the primary PCI is consistently recommended in recent and previous guidelines, the device lag from Europe, the frequent usage of coronary imaging modalities in Japan, and the difference in available medical therapy or mechanical support may prevent direct application of European guidelines to Japanese population. The Task Force on Primary Percutaneous Coronary Intervention of the Japanese Association of Cardiovascular Intervention and Therapeutics (CVIT) has now proposed the expert consensus document for the management of acute myocardial infarction focusing on procedural aspect of primary PCI

    Let-7 MicroRNA Family Is Selectively Secreted into the Extracellular Environment via Exosomes in a Metastatic Gastric Cancer Cell Line

    Get PDF
    Background: Exosomes play a major role in cell-to-cell communication, targeting cells to transfer exosomal molecules including proteins, mRNAs, and microRNAs (miRNAs) by an endocytosis-like pathway. miRNAs are small noncoding RNA molecules on average 22 nucleotides in length that regulate numerous biological processes including cancer pathogenesis and mediate gene downregulation by targeting mRNAs to induce RNA degradation and/or interfering with translation. Recent reports imply that miRNAs can be stably detected in circulating plasma and serum since miRNAs are packaged by exosomes to be protected from RNA degradation. Thus, profiling exosomal miRNAs are in need to clarify intercellular signaling and discover a novel disease marker as well. Methodology/Principal Findings: Exosomes were isolated from cultured cancer cell lines and their quality was validated by analyses of transmission electron microscopy and western blotting. One of the cell lines tested, a metastatic gastric cancer cell line, AZ-P7a, showed the highest RNA yield in the released exosomes and distinctive shape in morphology. In addition, RNAs were isolated from cells and culture media, and profiles of these three miRNA fractions were obtained using microarray analysis. By comparing signal intensities of microarray data and the following validation using RT-PCR analysis, we found that let-7 miRNA family was abundant in both the intracellular and extracellular fractions from AZ-P7a cells, while low metastatic AZ-521, the parental cell line of AZ-P7a, as well as other cancer cell lines showed no such propensity. Conclusions/Significance: The enrichment of let-7 miRNA family in the extracellular fractions, particularly, in the exosome
    corecore